Product Details:
|
Capacity: | 3 Tons | Lce Making Capacity : 3Ton/24hCompressor Rated Power: | 9KW |
---|---|---|---|
Circulating Water Pump Power : 0.75KwCooling Water Pump Power : 1.5KWCooling Fan Motor Power : 0.56K: | 0.75KW | Cooling Water Pump Power: | 1.5KW |
Cooling Fan Motor Power: | 0.56Kw | Lce Cutter Motor Power: | 0.75KW |
Lce Making Machine Size: | 1300x1100x2200 (mm) | Weight: | 1500KG |
High Light: | 3 Tons Tube Ice Maker,Cafes Bars Tube Ice Maker |
Selling Promotion Price 3 Tons Tube Ice Maker Making Machine For Cafes Bars
The tube ice machine is a rapid ice-making equipment that directly produces tubular small pieces of ice in the tube ice generator (a shell-and-tube evaporator). It does not need salt water, Russian ice shelves, water dispensers, etc. to make ice. It is the necessary equipment for the method, and it also has a large evaporation area, a high evaporation temperature, and a small footprint.
The tube ice produced by the tube ice machine is uniform in size, clean and transparent. The machine is produced with high-quality accessories and controlled automatically. The machine design shortens the deicing time as much as possible, thereby improving the ice making efficiency. The entire deicing time is controlled within 60-180 seconds. , is an excellent ice-making equipment.
1. Fast ice making: The tube ice machine designed with patented technology greatly shortens the deicing time, and the whole deicing is completed within 90 seconds, improving the ice making efficiency
2. Excellent material: Made of 304,316 stainless steel, beautiful, hygienic and easy to clean.
3. Automatic control: Microcomputer control system is adopted, which is easy to operate, safe and stable.
4. Energy-saving efficiency: Ice production speed is fast, the ice is dry and transparent, not easy to melt, the ice is clean, and the ice is released once every 15 minutes.
5. Structural optimization: Modular design, all parts of the machine can be disassembled and assembled, which is convenient for customers to maintain.
6. Scientific design and advanced processing technology The structure design of the tube ice machine is scientific, and the best ice-making system is tailored according to the actual needs of users. The world's advanced ice-making technology and processing and testing equipment are adopted, and each component is strictly controlled. It is processed according to the technical requirements and has undergone strict testing before use.
7.High reliability and low failure rate 80% of the accessories in the tube ice machine system adopt international famous brands. After years of research and practice, the product can run continuously without failure, maintain good operation and stable ice production at an ambient temperature of 5°C-40°C, and the specially designed model allows normal operation under the worst conditions ( -5°C-+56°C).
8. Safe and hygienic pursuit of manufacturing high-quality, high-hygienic tube ice equipment. All parts in contact with water in the equipment are made of SUS304 or SUS316L stainless steel and PE materials. The tube ice produced is odorless and clean, and the hygienic standards meet HACCP and PDA. certification requirements.
9. High Efficiency and Environmental Protection The tube ice machine operates continuously and stably, and realizes operation without energy waste; compared with other ice making equipment, it has the advantages of compact structure, small footprint, low production cost, high cooling efficiency, and energy saving.
Tube Ice Machine Parmeters
Model
|
Daily output
(T/24 h)
|
CompressorPower
|
Fan Power for Cooling Tower
|
Cooling
Pump Power
|
Unit size (L*W*H mm)
(Integrated Type)
|
Unit N.W.(kg)
|
|
TV 10
|
1
|
4.1 kw
|
0.25 kw
|
1.1 kw
|
1100*900*1780
|
900
|
|
TV 20
|
2
|
7.44 kw
|
0.25 kw
|
1.5 kw
|
1250*1000*1950
|
1200
|
|
TV 30
|
3
|
10 kw
|
0.55 kw
|
1.5 kw
|
1300*1100*2200
|
1500
|
|
TV 50
|
5
|
19.9 kw
|
0.55 kw
|
2.2 kw
|
1600*1400*2250
|
1800
|
|
Model
|
Daily output
(T/24 h)
|
Compressor
Power
|
Fan Power for Cooling Tower
|
Cooling Pump Power
|
Unit size (L*W*H mm)
(Split type)
|
Unit N.W.
(kg)
|
|
Main Host
|
Brine Tank
|
||||||
TV 100
|
10
|
27.9 kw
|
1.5 kw
|
4 kw
|
1900*1600*1850
|
1200*1200*3390
|
3500
|
TV 100+
|
10
|
39.8 kw
|
1.5 kw
|
4 kw
|
2400*1700*2000
|
1200*1200*3390
|
3700
|
TV 150
|
15
|
46.4 kw
|
1.5 kw
|
5 kw
|
2700*2000*2200
|
1500*1200*4250
|
4250
|
TV 200
|
20
|
55.7 kw
|
2.2 kw
|
7.5 kw
|
2800*2200*2500
|
1500*1200*4700
|
6500
|
TV 300
|
30
|
83.6 kw
|
2.2 kw
|
7.5 kw
|
3100*2200*2500
|
1800*1500*5700
|
7200
|
TV 400
|
40
|
111.4 kw
|
2.2 kw
|
11 kw
|
3900*2250*2500
|
2000*1500*6800
|
8300
|
TV 500
|
50
|
139.3 kw
|
3.75 kw
|
15 kw
|
4500*2250*2500
|
2200*1800*7200
|
9500
|
1. Compressor brand: Bitzer /Franscold ; Refrigerant: R 22/ R 404 A; Cooling Method: water cooling / air cooling.
2. Power supply:voltage 380V/3P/50Hz(for non-standard voltage, unit configuration needs to be calculated separately ).
3. Operating conditions: T (water supply):20℃ , T (ambient): 32℃, T(condensing):40℃, T (evaporating):-12℃. 4. (Note: The actual ice production varies due to the influence of water supply temperature and ambient temperature.) 5. (The final interpretation of the above mentioned parameters is in Icesource, there will be no further notice, if there any technical change. ) |
Contact Person: Henry Lin
Tel: 86-180 2621 9032
Fax: 86-20-39199299